info@picotest.com
1-877-914-7426
IMG-LOGO
IMG-PRODUCT
IMG-PRODUCT
IMG-PRODUCT
IMG-PRODUCT

P9610A/11A Mixed Mode Power Supply (Switched Efficiency + Linear Performance)

KEY FEATURES:

  • Highest Quality Yet Competitively Priced
  • Continuous Autoranging
  • Better Transient Response
  • Low noise - 35% less than competitors
  • Optical controls - Don’t get dirty or wear out
  • Programmed Power Sequencing Capability
  • Lightweight < 2.5kgs (5.5 lbs) and Stackable

What's included:

  • Power supply and power cord.
  • One (1) Year Manufacturer's Warranty
  • USB and GPIB interfaces on both models are optional. Bumpers are included with the P9610A. Bumpers are optional on the P9611A.

Visit the "Support Page" for more downloads.

Lightweight Autoranging Power Supplies
New 1 & 2 Port Probing Solutions

Questions? Don't hesitate to Contact Us

Subscribe to newsletter

Model Description Price  
P9610A P9610A Programmable Autoranging Power Supply (36V/7A 108W)
(USB, and GPIB Interfaces are optional. Bumpers are included.)
$735.00
P9611A P9611A Programmable Autoranging Power Supply (60V/6A 150W)
(Bumpers, USB, and GPIB Interfaces are optional)
$630.00
Accessories Description Price  
P20025B Front Bumper
$5.00
P20026A Rear Bumper
$5.00
PWR-opt01 USB Interface (including USB cord)
$25.00
PWR-opt02 USB and GPIB Interfaces (including USB cord)
$165.00
The P961xA Series of programmable DC power supplies gives you the performance of the top-of-the-line power supplies at an outstanding price. All models provide clean power, excellent regulation and a fast transient response. The P961xA Series is designed to meet the requirements of the most demanding applications in circuit design and verification, production testing, and quality assurance with the superior quality and reliability that you have come to expect from Picotest.
Single-Output Autoranging Power Supplies

These single output power supplies offer continuous autoranging, eliminating the need to manually select the optimum range. All of the power supplies power is available to you across the voltage and current ranges giving you the ultimate in flexibility. Output load is protected against overvoltage and overcurrent, which are easily monitored and adjusted from the front panel and remote interface. Remote sense is available to eliminate the errors due to voltage drops on the load leads.Low Noise and Excellent Regulation

Low Noise and Excellent Regulation

LESS than 0.01% load and line regulation keep the outputs steady and stable. Low noise assures clean power for precision circuitry while the low common mode current (< 1.5uArms) provides isolation from power line current injection.

Front Panel Operation

The intuitive interface allows you to monitor both voltage and current simultaneously for any one output from the front panel on an easy to read display. A optical knob doesn’t get dirty and allows you to quickly adjust the output at the resolution you need for precise and reliable results. You can program voltage or current sequences.

Remote Interface

All models come standard with USB and GPIB interfaces. You can program both voltage and current. In addition, you can monitor the output terminals for voltage and current, while a query command lets you read the programmed voltage and current. And programming is done in easy to use SCPI.

More Features:
  • Single output - Two Models
  • P9610A 108W (36V/7A), P9611A 150W (60V/6A)
  • Excellent Load and Line Regulation
    • < 0.01% + 2mV Voltage change for any load change
    • < 0.01% + 250uA Current change load for any load change
  • Very fast transient response times (<30us - P9610A/<50ms P9611A)
  • Very fast settling times (<40ms - P9610A/<50ms P9611A)
  • Constant voltage, constant current, programmed sequencing
  • High accuracy and resolution
    • Voltage 0.05% + 10mV (Output + offset)
    • Current 0.2% + 10mA (Output + offset)
  • Low ripple & noise
  • GPIB and USB Connections optional
  • Programming Compatible with the Keysight E3632A
  • No Shorting Bar Necessary
  • Remote sense, Master -Slave Operation (P9610A only)
  • Three-year warranty
Specifications
Output Ratings (@ 0°C ~ 40°C) (P9610A/P9611A)
Voltage: 0 to 36 V / 0 to 60 V³ (P9611A)
Current: 0 to 7 A / 0 to 6 A (P9611A)
Programming Accuracy¹ 1 Year (@ 25°C ±5°C), (% of Output + Offset)
Voltage: 0.05% + 10 mV
Current: 0.2% + 10 mA
Read-Back Accuracy¹ 1 Year (over USB or front panel with respect to actual output (@ 25°C ±5°C),
(% of Output + Offset)
Voltage: 0.05% + 5 mV
Current: 0.15% + 5 mA
Ripple and Noise (with outputs ungrounded, or either output terminal grounded, 20 Hz to 20 MHz
Voltage: < 0.35 mVrms / < 0.5 mVrms (P9611A)
< 2 mV p-p / < 3 mV p-p (P9611A)
Current: < 2 mArms
Common Mode Current: < 1.5 µArms
Load Regulation ±(% of Output + Offset)
Change in output voltage or current for any load change within ratings.
Voltage: < 0.01 % + 2 mV
Current: < 0.01 % + 250 µA
Line Regulation ±(% of Output + Offset)
Change in output voltage or current for any load change within ratings.
Voltage: 0.01 % + 2 mV
Current: 0.01% + 250µA
Programming Resolution
Voltage: 1 mV
Current: 0.21 mA / 1 mA (P9611A)
Read-Back Resolution
Voltage: 1 mV
Current: 0.1 mA / 0.21 mA (P9611A)
Meter Resolution
Voltage: 1 mV / 10 mV (P9611A)
Current: 0.1 mA / 1 mA (P9611A)
Transient Response Time
Less than 30/50 usec for output recover to within 15 mV following a change in output current from full load to half load or vice versa.
Command Processing Time via GPIB
Read-Back Commands: Maximum time to read-back output by MEASure? commands < 20 ms
Output Programming Range (maximum programmable values)
Voltage: 0 to 37.8 V / 0 to 60 V (P9611A)
Current: 0 to 7.35 A / 0 to 6 A (P9611A)
Temperature Coeffiecient ±(% of Output + Offset)
Maximum change in output / read-back per °C after a 30-minute warm-up.
Voltage: 0.01 % + 3 mV / 0.01 % + 10 mV (P9611A)
Current: 0.02 % + 3 mA
Stability (% of Output + Offset)
Maximum change in output / read-back per °C after a 30-minute warm-up.
Voltage: 0.02 % + 1 mV / 0.05 % + 10 mV (P9611A)
Current: 0.1 % + 1 mA / 0.15 % + 2 mA (P9611A)
Voltage Programming Speed
Maximum time required for output voltage to settle within 1 % of its total excursion (for resistive load). Excludes command processing time.
Full Load Up (0V ~ 36V): < 40 ms / (0V~60V): < 100 ms (P9611A)
Full Load Down (36V ~ 0V): < 40 ms / (60V~0V): < 50 ms (P9611A)
No Load Up (0V ~ 36V): < 20 ms / (0V~60V): < 35 ms (P9611A)
No Load Down (36V ~ 0V): < 400 ms / (60V~0V): < 500 ms (P9611A)
General Specifications²
Item Limitation & Description
Power Supply: 100V ~ 120V (115V Range)
220V ~ 240V (230V Range)
Power Line (Hz): 47Hz ~ 63Hz
Interfaces: USB & GPIB
Power Consumption: 400VA Maximum
Size & Weight for Rack (WxHxD): 214.6 x 88.6 x 280 mm, < 2500 g (5.5 Lbs)
  1. 1. The accuracy specifications are gained under 1-hour warm-up condition and the calibration at 25°C.
  2. 2. For more information, please check the user's manual.
  3. 3. The red supplements are the P9611A's specifications. If there is no red, the specs. are the same as the P9610A's.

The specifications are subject to change without notice due to design improvements.

Question: Why buy a refurbished E3632A when you can get a new superior yet compatible P9610/P9611A at a lower price with a 3 year warranty?

PICOTEST POWER SUPPLY COMPARISON SHEET
Function Model P9610A Model P9611A Model E3632A
VA Power 108W 150W 120W
Linear/Switch/Mixed Mixed Mixed Linear
Single Output Yes Yes Yes
Autoranging Yes Yes No, two ranges
Output
Voltage & Current
0 to 36 V
0 to 7 A
0 to 60 V
0 to 6 A
0 to 15V/7A
0 to 30V/4A
Transient Response < 30 µs < 50 µs < 50 µs
Ripple & Noise Voltage
(20Hz to 20MHz)
< 0.35 mVrms
< 2 mVp-p
< 0.50 mVrms
< 3 mVp-p
< 0.35 mVrms
< 2 mVp-p
Ripple & Noise Current &
Common Mode Current
< 2 mArms
< 1.5 uArms
< 2 mArms
< 1.5 uArms
< 2 mArms
< 1.5 uArms
Master-Slave Control Yes No No
Remote Sensing Yes No Yes
Programming Accuracy
Voltage & Current
0.05% + 10 mV
0.2% + 10 mA
0.05% + 10 mV
0.2% + 10 mA
0.05% + 10 mV
0.2% + 10 mA
Read-Back Accuracy
Voltage & Current
0.05% + 5 mV
0.15% + 5 mA
0.05% + 5 mV
0.15% + 5 mA
0.05% + 5 mV
0.15% + 5 mA
Programming Resolution
Voltage & Current
1 mV
0.21 mA
1 mV
1 mA
1 mV
0.5 mA
Read-Back Resolution
Voltage & Current
1 mV
0.1 mA
1 mV
0.21 mA
0.5 mV
0.1 mA
Meter Resolution
Voltage & Current
1 mV
0.1 mA
10 mV
1 mA
1 mV
1 mA
Output Programming
Range (Voltage & Current)
0 to 37.8 V
0 to 7.35 A
0 to 60 V
0 to 6 A
0 to 15.45V/7.21A
0 to 30.9V/4.12A
Stability
(Voltage & Current)
0.02 % + 1 mV
0.1 % + 1mA
0.05 % + 10 mV
0.15 % + 2 mA
0.02 % + 1 mV
0.1 % + 1mA
Short-Withstood Circuit Yes Yes Fair, weaken power
Sequencing Mode Yes Yes No
OVP/OCP/OTP Yes Yes No OTP
Optical Knob Yes Yes No
No Shorting Bar Yes Yes No
Front & Rear Bumper Yes Optional ($15) Yes
USB or USB/GPIB Interfaces Optional ($25/$95) Optional ($25/$95) Yes
Size & Weight 21.5*8.9*28 cm, < 2.5 Kgs 21.5*8.9*28 cm, < 2.5 Kgs 21.3*13.3*34.8cm, 9.5 Kgs
Voltage Programming Speed
Full Load Up (0V~36V) (0V~60V) (0V~30V)
< 40 ms < 100 ms 50 ms
Full Load Down (36V~0V) (60V~0V) (30V~0V)
< 40 ms < 50 ms 45 ms
No Load Up (0V~36V) (0V~60V) (0V~30V)
< 20 ms < 35 ms 20 ms
No Load Down (36V~0V) (60V~0V) (30V~0V)
< 400 ms < 500 ms 400 ms