info@picotest.com
1-877-914-7426
IMG-LOGO
IMG-PRODUCT
IMG-PRODUCT
IMG-PRODUCT
IMG-PRODUCT

J2160A 2-Port Probe Adapter Panel for the E5061B

KEY FEATURES:

  • Low noise, compact adapter with internal 6dB port splitter
  • Supports 2-port shunt-thru and ultra-low impedance measurement
  • Rugged, comfortable, ergonomic design; slim form factor
  • Two semi-floating ports
  • Easy to attach and detach
  • Neater connections consume less bench space
  • Works with the Port Saver DC Blocker

What's included:

Probe Adapter Panel for the E5061B ENA's T/R Ports
-- Includes the 6dB resistive port splitter internal to the adapter
One (1) Year Manufacturer's Warranty

Data Sheet
Press Release

Questions? Don't hesitate to Contact Us

Subscribe to newsletter
Model Description Price Cart
J2160A 2-Port Probe Adapter Panel for the Keysight E5061B ENA T/R Ports
$395.00
The Picotest J2160A Probe Adapter provides a low noise, compact solution when using the E5061B T/R ports in a 2-port shunt thru measurement. The T/R ports are desirable for low frequency 2-port measurements, since these ports are semi-floating, allowing low impedance measurements without the use of a coaxial common mode transformer such as the J2102A. The floating ports allow milliohm measurements even at very low frequency and up to the 30MHz range of the T/R ports.

The current solution uses a resistive 6dB port splitter combined with coaxial cables to support this measurement. The J2160A is a slim profile adapter, converting the three E5061B BNC ports to two BNC ports for the 2-port measurement. The 6 dB resistive port splitter is included internal to the adapter so no external splitter or cables are required. The short connections are neater, consume less bench space, and can result in a lower noise measurement.

The adapter can also be combined with ultra-wide bandwidth DC blockers, such as the Picotest Port Saver. This allows you to make 2-port measurements of sensitive devices without the 50 ohm DC port loading, which could overload the device being measured and/or severely distort the measurement results.

The Picotest adapter also supports the extended 2-port shunt thru measurement, allowing higher impedance 2-port measurements by adding a series resistor to each port. [1]

Setup files for various values of resistance are available for FREE on the Picotest website in the Support section here.

References
1) Increase Range in 2-port Impedance Measurements, EDN, May 04, 2015
The specifications are subject to change without notice.

Caution: To avoid equipment damage and/or severe injuries death or death do not use this probe close to voltages higher than 50 VAC or 75 VDC.

The probe has 50 ohm compatibility with all equipment including VNAs, Oscilloscopes and Spectrum Analyzers.

Copyright © 2023 Picotest. All rights reserved.